hayward blue essence troubleshooting

Thanks for your time. Hi, my name is Javier Hi Davy, I have a brand new Hayward motor/pump as shown above on your site. We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. ring wont spin loosely around but it didnt seem to help. Power on LED is intermittently on or off. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. 4. The pump is working fine, however only the low speed is working. There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. I have cleaned the rubber gasket, made sure the springs touch to no avail. A pool guy who has since stopped operating put it in. Other timers will have a different switch, but all should have someway to override. Product Type Model Name Select Model # HI David, did anyone empty the pump basket recently? Will it do it any harm if we leave it running? For a DE filter, pull out the grids and clean them off. Its running now but when I turn it off it wont restart. The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. It could be dead. Low speed should be enough flow to activate the flow switch. "author": {
Check the mechanics of the switching mechanism. I was hoping that you can give me some advice. Good luck! If its not the cord, I would suggest the filter, cleaning the fingers with a good soak to de-scale and de-grease. The problem lies, where the power dies as they say. My Hayward pump is only about 3 yrs old. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). Came out tonight and flipped the switch and pump started. have the pump motor rebuilt by replacing the bearings and shaft seal, or having an electric motor repair shop do it for you, or 2) replace the motor with an exact replacement motor + new shaft seal, or 3). likely not a fan or impeller problem, because at 3500 RPM (or less), it would wear down anything broken in just a few minutes. Hayward Super Pump, 1 Hp running on 240V, 3 yrs old Is there a solution for this problem? Is it possible pump too small for AV60 filter? Step 5: Measure your cells polarity to ensure they meet system parameters. Hi Sara, could the sound be the gas whistling thru the burner orifices? Any thoughts? "publisher": {
We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Checked the circuit breaker and turned it off and on. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. What am I missing? However, when I check the connection at the wired, there is definetly juice there. We opened our pool a week ago and havent had a problem until today (May 23. Contact a professional for further assistance. If you see any damage, replace your flow switch. Is this rare? Could this be an issue with my pump? If all looks tight you may need a new Max-Flo II motor or a new Max-Flo XL pump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. Pressing on/off buttom followed only by click sound of switch. Breville Tamper Coffee Kit 54mm, Heat exchanger has to be getting too hot? The problem lies where the power dies! Internal electrical faults in the pump, such as a short circuit or improper ground, also can cause the device to draw more power than necessary and excess heating. Its a 16-14 250 amp connection. Inspect the capacitor (black cylinder, 9 oclock) and the centrifugal switch, (on the end of the motor shaft), for any signs of damage or looseness. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. So we have power to the pump. this is the black cylinder in the rear, at 9 oclock. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. Perflex filters can clog up with heavy oils, or not enough DE powder, or if undersized for the pool (just like any other filter), so it could be the filter yes. If you have trouble getting past this, an electrician may be a good call to make. Hi, I have a Hayward pump and it was running my barracuda g3 just fine but it stopped hours later. Or third, it could be low voltage or a bad power cord, or loose power wire connections, or broken wires. Heaters often normally make such sounds, could also be debris laying on top of the burners. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? How are you supposed to move the shaft several revolutions with a 7/16 wrench with all the pegs in the way and the shaft only having two flat sides to get the wrench to lock on to it??? IF the motor is turning over or starting, but no water pumps, it is usually an air leak from a loose pipe coming into the pump, or a loose pump lid. I recently took it ofdf to install a new spider gasket and saw no obvious reason for the leak. Also check that wires are tightly attached, at breaker, timer and pump. If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). Or using a Clarifier after vacuuming can also be a solution. When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. Could need cleaning. Hayward Aquarite T-CELL-5 | 20,000G Replacement Cell - Salt Pool Store Most heaters can operate on 120V/240V, either one. The pump does not start. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). put on high speed. Any insight would be helpful. 4 New pump 2 years old. New pump, was running fine. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. 3. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Capacitors are cheap to replace, order the exact MFD number, printed on it, or you can pick up local at a motor shop. Is the wire the correct size wire? What should i do now? , I have a 1 hp Hayward 2 speed motor. "name": "Mark Garcia",
Any ideas why? Unlike the error codes that show up on the digital screen, these problems dont show up as an error notification. There may be some stray voltage running around the system, on the bonding wire. You can also contact Hayward Technical Service for help directly at (908) 355-7995. Still same though nothing being sucked through basket and minor trickle back out into pool. I was wondering, I have four returns coming into one pipe to the pump basket. Tried again and again to start, but just keep hearing a click sound and nothing happens. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. If there isnt any apparent damage, keep reading. BUT THE BEARINGS. Any suggestions. My question to you is what to do from here. Check all wires, to be sure that the metal ends of wires are not touching any metal ends of the motor housing, or contacting other wire metal ends. You can also call Hayward directly for tech support. Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. After resetting the switch 3 times yesterday,the pump is finally staying on. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Im losing my mind. Do I need to use lube on the gasket, how much sand should be in the filter? Is it problem of filter ? So I messed with the wires a little and I got it to turn back on. If that does not fix the issue, the problem goes deeper, and it may be a fatal error in the motor. Our variable speed Hayward pump, when not running on highest speed, keeps resulting in FLO errors. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. I couldnt believe it..after two weeks and a new pump! Going to try 2 hrs low and 6 high. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! Approx. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? Any suggestions? Thanks, Steve DeGray. We only use the pump in the summer months, since we live in Canada. Hopefully it has a switch inside the pump so I can change it for 115. this year, pressure goes up to 30psi. What should I check? 7. inspect breaker, turn off breaker to pool from house main panel). ), it could be a bad breaker, they can fail or become too sensitive with age. Then hold the shaft stationary to remove the impeller, and finally remove the housing. Hi Davy~ 2. pump lid Hi Rob, I think its a one-year warranty? Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. Any ideas why this would happen? It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. First, in regard to my Hayward pump basket lid, it is hard to turn counter clockwise, when i need to remove it but it does turn. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. If the gears are moving, then power should be coming out of the timeclock to the motor. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. Yesterday I plugged it in to filter and where the plug goes into the 3 foot heavy duty extension it sparked smoked and created a small flame. Attach a bond wire to the Eco star drive pump or tighten the loose screws on the bottom of the motor. I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. If youre correct that theres a problem with the internal bypass, what should I do? There is water under the motor not sure from where. When the pool guy switched it, it worked very well for about a month with no issues at all. Hi Amy, the timer is usually wired between the pump and the breaker. Please note: The majority of our literature and brochures are in English only. If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. We have parts for the Super pump. If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. At a total loss here, any suggestions would be greatly appreciated. That is usually suitable, but 20 amp could also be used. Is this normal operation or should I look into replacing the strainer cover o ring? Also look for loose wires or corrosion (stored next to chlorine tabs during winter?) Hi Toula, consider that the impeller may be clogged, or you may have an air leak, in front of the impeller. Hi, when my Hayward pool heater is on Im getting a sour odour from the exhaust. I dont really know if my pump can be repaired or if the only solution is buying a new pump so soon. If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. 25 LibriVox About. Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. Hi Andy, good question thanks Motor will start on low, but not on high. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. },
Sorry for the bad news. If they are within range, replace the drive. I can turn the switch to low and it will start and run then switch to high. BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. Now I am looking to replace the old filter. This past week the motor sometimes starts sometimes does not sometimes starts and turns itself off. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. In the last couple weeks it started getting louder at various times throughout the day. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Motors have a thermal overload switch (in the rear of the motor, top-dead-center, at 12:00). Perflex filters are particularly known (to me anyway) for building up oily deposits on the fingers or flex tubes, and clogging up quickly. Check the capacitor, for bulging, cracking, or melting. I used no lube on the gasket. cd77petanque.com Informacin detallada del sitio web y la empresa What do you suggest? well, possibly it just needs to dry out. Chapter 1: The Evil Emperor's Son. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. Also, I wonder if it matters or not which filter would be best, the Hayward EC50AC (AG), or sp2607x10 EC65A (IG). Upon restart, pump sounds horrible, like pumping rocks. could be cord problem, too. That is usually the capacitor, a black cylinder in the back of the motor. Flipped the breakers back on this morning after problem fixed. I added new wire and plug end but when I plug it in it trips the breaker. If low flow is not caused by a clogged strainer, inspect the cleaner hose for pressure loss (leaks). After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. At75%, or lower, in either polarity, it's time to consider replacing the cell. Chlorinator Pro CP-15 Cell. A leaking shaft seal or drain plug could also drain the pump after some time. Diagnosing and Troubleshooting Your Hayward Aqua Rite System - INYOPools The price seems steep ($500+ for the pump) and it seems only Leslies carries them. Guess I was wrong. Hi and thanks for all this knowledge! Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Automatic restart 2 minutes after error is corrected. If you have found a burnt spot or something broken on the circuit board, that is a likely power killing area. Good luck! I have it set to run for 3 hours in low speed and 5 in high. I used electrical tape so the impeller larger hp motors, are not reversible. Find these plugs and remove them by loosening the wingnut and wiggling it out. 2 year warranty. If control input data is corrupts, the heater will shut down and lockout. Or use this Pump Cord. A bad shaft seal or loose pipe is likely the cause of your leaky pump. What am I not doing? You find these in our valve parts department or use one of our multiport valve rebuild kits. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. $579 + Free Shipping in USA. Anything I can do on my own to fix this? was spinning counter clockwise. The pump said it came prewired for 230V, but we are running 115V. hi I followed the set up directions on my new sp1580lx pump and it keeps tripping the breaker. iv also replaced o rings and filter basket gasket. 7 yrs old and used year round. You are also using the diffuser? Ive tried the override, checked the basket on the pump and felt into the intake and outlet for obstructions. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). Be sure that all pool valves are open and any wall plugs are removed before turning on pump. Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely.